Roofing in LadueKeys Roofing

Roofing, gutters, downspouts

(314) 220-2333

Roofing in Ladue › Gutters on a large house

Article 07 · Gutters

An Outdoor Kitchen Vent in Your Soffit Needs a Name Before the Tear-Off

A built-in outdoor kitchen hood can vent through the eave you are replacing. Name who cuts it, flashes it and checks the duct before the tear-off.

Gutter is the least glamorous part of a roofing job and it causes more expensive damage than any other part of it, because water that misses the gutter does not go away. It goes to the foundation, and foundation water on a large old house is a five figure conversation with a different trade entirely.

A built-in outdoor kitchen brings its own exhaust. The hood over the grill or the side burner needs a duct, and on many Ladue lots that duct climbs the back wall and exits through the soffit at the eave. When the roof comes off, that opening is one more penetration in the surface the crew is about to strip, and it sits right where the ladder goes. Roof bids often skip it because the hood was installed by a different trade, years after the roof went on. This page gives you the questions to put to each roofer before you compare numbers.

Town roofing

Ladue houses often have deep eaves, long soffit runs and brick or stone walls that rise to a roof line built to shed water well out from the wall. An outdoor kitchen tends to sit under that eave because it is sheltered from the weather and close to the house door. That spot is sensible for cooking. It also puts the hood vent exactly where the crew will stand, stage bundles and run the magnet over the drip edge.

St. Louis winters work on every sealed joint. The freeze thaw cycle opens a bead of sealant around a vent face, and water gets behind the soffit panel and runs along the fascia before anyone sees a stain. The same cycle lifts the edge of a cap that was set on a bed of caulk instead of being flashed in. Look at that joint from below before the roof bid is written, not after the first hard freeze.

Ice at the eave adds a second risk. When an ice dam forms, water backs up under the first course of shingles, and the soffit is often the first place it shows. A duct that ends inside the soffit cavity instead of outdoors can push grease-laden kitchen air into the same cavity that feeds the attic ventilation. That is a mechanical fault, not a roofing fault, but the roofer will be the one who opens the eave, so it is worth asking who checks it.

Hail season in the metro runs through spring and into early summer. A hood cap, a sheet metal vent face or a louver on the soffit takes hits like anything else on the house. Photograph these with the rest of the eave, because a dented cap is easy to miss when attention is on the shingles. If hail has marked the cap, Keys Roofing can document it with photos and measurements and put a written scope in your hands. Missouri law (RSMo 407.725) bars a roofing contractor from representing or negotiating your insurance claim, so the conversation with your insurer stays with you.

The permit question is local. Building work in Ladue runs through the municipality that covers your address, and a new gas line or a new circuit feeding the outdoor kitchen may need its own permit and inspection, separate from the roof. Ask the roofer whether the duct, the gas and the electrical work are already permitted, and check that answer with the building office. A crew member's memory of the last job is not a permit record.

What it costs

Nobody can give you a fair number for the vent until the penetration has been seen. A bid should split the work into lines you can compare, and the duct itself is usually another trade's job. Stainless and galvanized ducts behave differently at their seams, and a seam that sits inside the soffit gets hot in summer and cold in winter, which loosens screws over time. Ask what the duct is made of and where its joints sit. For the roof side of the work, look for separate lines covering:

  • Removing and resetting the soffit panel or vent face around the duct
  • Flashing or collaring the duct where it passes through the eave
  • Any new blocking or framing needed to hold the cap securely
  • Sealant rated for exterior exposure at each joint, with the product named
  • Disposal of the cut panel and any old caulk removed from the joint
  • Protection for a grill, gas line or patio surface that stays in place during the work

If the duct has to move, the rerouting belongs to the company doing the outdoor kitchen work. The roof bid should show only the roof penetration, and it should say where the line between the two trades falls. A bid that says the vent is included without describing it is a bid that will be argued over on the last day.

Do not accept an allowance line for the vent unless it names a dollar figure and a condition for using it. An allowance that grows after the eave is open is a change order in disguise, and it leaves you choosing between paying more and leaving a bad seal under the new shingles.

What to ask

Ask each roofer these questions before you compare totals. The answers will show whether the bid has looked at the vent at all.

  1. Where does the hood duct exit: the wall, the soffit or the roof?
  2. Who cuts the soffit, and who replaces the panel when the crew is done?
  3. Is the cap a kitchen-rated exhaust termination or a standard gable vent louver?
  4. Who checks that the duct ends outdoors and not inside the eave cavity?
  5. Which permit covers the duct, the gas line and the circuit, and who pulled it?
  6. Who photographs the penetration before the tear-off and again after the seal is done?
  7. Who answers for the seal if it weeps during the first freeze?

Before the crew arrives

Clear the outdoor kitchen before the roof truck comes. Cover the grill, move the chairs and take any propane tank out from under the eave, because the crew will need that corner for staging. Tell the roofer where the gas shutoff is and which valve feeds the hood, so that nobody has to guess during the work. If the cooktop is in use during the tear-off, ask the crew to plan their noisy hours around your meals rather than working directly above the grill.

Keep the written scope and the photo log together in one folder. When the crew has finished and the cap is set, you should be able to match each line in the bid to a photo of that line in place. If a line has no photo, ask why before the final payment.

Keys Roofing can walk the eave with you before the quote is written. The office number is (314) 220-2333.

Ask about your roof

If it overflows in the same spot every time

A gutter that fails in one predictable place is usually telling you it needs an outlet, not a replacement.

Seamless gutter formed on site, guards, downspouts, extensions and underground carry.

(314) 220-2333

Straight through to the office