A Snowmelt Drive Puts Water and a Flue at the Roof Edge

A heated drive can melt snow onto your eave and hide a boiler flue. Settle both with the roofer before the tear-off date is set.

Gutter is the least glamorous part of a roofing job and it causes more expensive damage than any other part of it, because water that misses the gutter does not go away. It goes to the foundation, and foundation water on a large old house is a five figure conversation with a different trade entirely.

A snowmelt drive is a slab or paver field with tubing set a few inches down, fed warm water or glycol from a boiler in the garage or a mechanical room. On a cold morning it keeps the snow off the apron, and on a roof job it can send meltwater straight at the eave. If the crew is planning a tear-off, the drive matters twice. It is where trucks, dumpsters and pallets will stand, and it is often where the boiler flue or its intake leaves the house. Neither one appears in a roof quote unless someone asks for it. This page covers what to settle on the drive and at the flue before the tear-off date is fixed.

Town roofing

Heated drives are common on larger lots in Ladue and across west St. Louis County, where a long run from the garage to the street would otherwise need shoveling every January. The loop is usually cross-linked polyethylene tubing, set in a grid below the slab or in a sand bed under pavers. A boiler, sometimes a heat exchanger tied to the house boiler, heats the loop. A snow or moisture sensor and a controller decide when it fires. Many owners run it on a timer from late fall into March, then shut it down for the warm months, and some leave it on a manual switch so it only runs when a storm is coming.

You can tell whether a drive is heated before anyone calls. Look in the garage or utility room for a manifold, a row of valves with flow gauges, and a small box on the wall with a dial or touchscreen. Outside, a few spots on the drive stay clear after light snow when the rest is white, and a sensor may sit in the paving near the apron. If there is a separate vent pipe on the wall near the eave, trace where it goes before the ladder goes up, since the roof work has to step around it.

The roof problem starts at the edge of that slab. When a drive is heated, snow that lands on it melts and runs toward the lowest point, which is usually the apron nearest the house or a drain at the garage door. If the heated area reaches under an eave, meltwater can run under the gutter line and refreeze at the drip edge on a cold night. A roofer who sees a heated slab running up to the eave should treat that eave as a warm edge with a water load, and the drip edge, underlayment and ice and water membrane should be extended to match. Ice at that eave is often meltwater the roof plan never accounted for, and attic heat is only part of the story.

The boiler flue is the second problem, and it is the one that gets left off the roof bid. A condensing boiler usually vents through a sidewall with plastic pipe and a terminal near grade or eave height. An older atmospheric boiler may run its flue up the house and out through the roof in a metal chimney or a vent cap. Either way the roof crew needs the exact location, the height of the terminal, and the clearance from the new shingles, ridge work and any gutter or soffit nearby. A flue through a roof slope needs a flashing and collar of its own, and a terminal close to the eave needs the wall and soffit checked before the first course of shingles goes on. Measure it, photograph it from the ladder, and put the photo in the file.

Missouri does not license roofers at the state level, so the roofer is not the person who should sign off a boiler or its vent. The mechanical side belongs to the heating contractor who installed or serviced the unit, and the permit record for that work sits with the local permit desk where the house is. For a Ladue address or any St. Louis County address, the roof contractor should not assume the boiler was permitted. Ask the homeowner or the heating contractor for the record before the flashing is measured, because a vent that was never inspected can change the roof plan on the day the crew arrives.

What it costs

A snowmelt system is a heating and plumbing asset, so it does not belong on the roof number itself. The roof bid may carry a line for flashing a flue or sealing a penetration, and that line is small next to the trip itself. The costs that do move come from the drive. They include protection boards or plywood on the heated area for trucks and dumpsters, a second dumpster placement if the first one cannot sit on the drive, and a labor line if the tear-off runs into a cold stretch and the crew has to work around tarps and heated slabs. A cracked slab from a dumpster leg or a loaded pallet is concrete repair, and it sits outside the roof price unless the bid names it.

Ask for the flue work by name. A bid line that says flashing is not enough. It should say which flue is being flashed, whether it goes through the roof or the wall, what material the collar and boot are made of, and who does the work if the flue sits on a part of the house that needs carpentry. If the boiler must be removed, moved or relocated for the roof job, that is a heating call. The roof bid should say the roofer will not disconnect it, and that the heating contractor will be on site for the disconnect and reconnect.

Cost also depends on timing. A tear-off in the cold season can mean the drive is frozen, the controller is set to run, and the crew has to plan around meltwater on the slab. Ask whether the bid assumes the snowmelt is off during the work, who turns it off, and who turns it back on at the end. The answer changes whether the roofer needs a standby day if the forecast turns.

What to ask

Before the crew walks the drive, get written answers to these questions on the job sheet:

  • Where does the snowmelt loop run, and how deep is the tubing under the slab or pavers?
  • Where does the boiler flue or its intake exit the house, and is it through the roof, a gable or the wall?
  • Which heated areas will carry the dumpster, pallets and trailer, and what protection goes under each one?
  • Who turns the controller off before the tear-off and back on after the final walk?
  • Does meltwater from the drive reach the eave, and is the drip edge or ice and water membrane extended to cover that run?
  • Who holds the permit record for the boiler, and where is it kept?

Some of these answers come from the roofer, such as the protection plan and the eave detail. Others come from the homeowner, such as the controller and the permit record, since the boiler and its paperwork belong to the house. Once each one is in writing, the crew has a map of the drive, the flue and the eave before a single bundle lands on it. Keys Roofing can be reached at (314) 220-2333 to walk the drive and the flue on a site visit before the tear-off date is set.

Ask about your roof

If it overflows in the same spot every time

A gutter that fails in one predictable place is usually telling you it needs an outlet, not a replacement.